FELEVATOR

The FELEVATOR journal

S3600/S3300AP Elevator STM Parameter Configuration Guide (SW V10.07 + STMM+)

Discover the Sch**dler S3600/S3300AP STM Parameter Configuration Guide (SW V10.07 + STMM+). Optimize your settings for better performance today!

FELEVATOR2 min read
Read the article
S3600/S3300AP Elevator STM Parameter Configuration Guide (SW V10.07 + STMM+)
The FELEVATOR journal

1. Purpose

To configure STM monitoring parameters for S3600/S3300AP elevators using software V10.07 and STMM+. Incorrect settings post-initial learning trip trigger "97" status (persistent error with limited operation).


2. Critical STM Parameters (Menu 40 → CF28)

CF PA Parameter Value Range Description Access
28 2 STM Bend Count Warning 50–90% % of max trips to trigger STM replacement warning (read-only, chipcard-derived) SIM ≥10.00
28 3 STM Bend Count Limit 0–108,000
(1=1,000 trips)
Max permitted trips. Exceeding causes elevator shutdown (read-only, chipcard-derived) SIM ≥10.00
28 4 STM Manufacturing Date 10100–75399
(DWWYY format)
Mandatory setting:
-D: Weekday (1–7)
-WW: Year week (01–53)
-YY: Year (00–99)
SIM ≥10.00
28 8 STM Aging Limit 0–65,000
(1=1 month)
Max STM age. Exceeding causes shutdown (read-only, chipcard-derived) SIM ≥10.00
28 9 STM Bend Counter 0–4,000,000
(1=100 trips)
Editableonlyafter activating Menu 190 Requires Menu 190

3. Procedure: STM Manufacturing Date Retrieval

Schindler S3600/S3300AP STM Parameter Configuration Guide (SW V10.07 + STMM+)

  1. Access STM Belt:

    • Position car at roof-access level using inspection mode.

    • Locate 5-digit code on STM belt back (e.g.,27942):

      • Digit 1 (D):Weekday (1=Mon–7=Sun)

      • Digits 2–3 (WW):Year week (01–53)

      • Digits 4–5 (YY):Year (00–99)

    • Example:27942→ Weekday 2 (Tue), Week 79, Year 42.

  2. Record Oldest Date:

    • Note the earliest manufacturing date across all belts.


4. Configuration Steps

  1. Post-Learning Trip:

    • Elevator enters normal operationOR"97" status.

  2. Set Date/Time (Menu 40):

    • Configure local time/date via:

      • CF04 PA2(Time)

      • CF04 PA5(Date)

  3. Input STM Date (CF28 PA4):

    • Enter 5-digit code from Step 3.

  4. Reset & Verify:

    • Exit config mode → SetMenu 101 = 1(fatal error reset).

    • Perform system reset.

  5. Validate Settings (Menu 60):

    • 601: Trip count (1 unit = 100 trips)

    • 631: ≈601 × 3(S3300AP)or601 × 2(S3600)

    • 632: STM expiry date (manufacture date + 15 years)


5. Troubleshooting

  • Mismatched631Value?

    1. SetMenu 190 = 1(5-minute edit window).

    2. EnterMenu 40→ AdjustCF28 PA9:

      • S3300AP:Value = Menu 601 × 3

      • S3600:Value = Menu 601 × 2

      *Note: 1 unit = 100 bends*

    3. Exit config mode.


6. Error Handling

Error Cause Solution
97 Status Missing/invalid STM parameters ConfigureCF28 PA4+ reset
4611 Commissioning number error EditCF28 PA6after activating Menu 190

This guide ensures compliance with SW V10.07/STMM+ requirements. Retain chipcard-derived defaults unless manual override is necessary.

Working on a similar project?

Send a part number or photo. Our team can help with the next step.

Ask our team

Let’s get to work

Your next part.
One conversation away.

Send us a part number or photo. We’ll help you check the details, availability, and shipping options.

felevator@outlook.com

Part number · Model · Quantity · Destination

Image detail